Applications
Diesel Engine Fan Clutch Control System
Operation |
When setpoint temperature is
reached, normally open terminal will close or conduct and normally closed
terminal will open or stop conducting. Temperature must then drop below setpoints
minus hysteresis or deadband value before the output terminals will return to their
normal state.
|
Specifications |
| Supply Voltage |
10 to 31 VDC |
| Reverse Voltage Protection |
Standard |
| Load Current Rating |
Up to 3 Amps Resistive, Current
Sourcing |
| Control Type |
On/Off (Both NO and NC Outputs) |
| Setpoint Tolerance |
+/- 2.5 degrees F |
| Control Hysteresis |
7 +/- 2 degrees F |
| Response Time |
4 Seconds 63.2% Step Function
Change |
| Packaging |
1/2 - 14 NPTF Threaded Brass
Housing |
| Terminations |
Screw Terminals |
| Operating Temperature Range |
-50 degrees to 250 degrees |
| Storage Temperature Range |
-50 degrees to 260 degrees |
| Humidity |
to 100% condensing |